Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13676683
![](http://i.b2b168.com/e/tag_pthy.gif)
- Product Categories
- Friendly Links
Information Name: | Clearance sale cheap rental 8590A 8590A 8590A not later |
Published: | 2015-05-27 |
Validity: | 360 |
Specifications: | 8590A |
Quantity: | 50.00 |
Price Description: | |
Detailed Product Description: | Clearance sale cheap rental 8590A 8590A 8590A not later Name: Zeng Manager Company Name: Bao'an District, Shenzhen, Qian Feng Electronic equipment firm Address: Bao'an District of Shenzhen City three Longjing Road 1, 27th Floor, B1 Dongjiang Haoyuan room quality, service sincerity! Your satisfaction is my pursuit! Give me a chance, I will give you a surprise! commitment strive to be more reliable, better quality service and strive! Qian Feng Technology was established in 2007, it is located in Chungli, Taoyuan City, Taiwan District, Shenzhen Branch The company is located in Bao'an District of Shenzhen City, three for the professional second-hand electronic test equipment suppliers. The company has a number of engineers, maintenance engineers and business electronic equipment industry was born, the accumulated more than ten years of rich technology and experience available to high-tech products used test equipment integration solutions, you save considerable equipment investment costs. Provide professional testing equipment sales, leasing and maintenance services, so you get higher profits at minimum cost. Customers in Europe, America, Japan and South Korea, mainland China and Taiwan, in today's highly competitive market diversification division, Qian Feng technology to instrument regeneration, integrity and expertise as the different needs of the core business triangle, in order to grasp market trends to meet customers. Which sells brands including HP / Agilent, Anritsu, Advantest, Rohde & Schwarz, Tektronix, IFR / Marconi, Keithley, Hitachi, Panasonic, Fluke, Iwatsu, Lecroy and other world famous brands. Equipment sales include network analyzers, spectrum analyzers, oscilloscopes, Bluetooth tester, signal generator, power equipment and other high-tech industries. 8590A long-term sale / lease / maintenance, low price, low-cost lease, best fare sale / lease, please contact us, thank you! ! ! Brief 8590A * 8590A * 8590A portable spectrum analyzer analyzer 8590A details * The ease of use, extended harmonic spectrum analyzer * There is a diverse range of price and performance * with a selectable button for FFT, TOI, ACP and other measurements * with extended memory and a tracer storage * Optional narrow resolution bandwidth * can provide customized special test software Product Description 8590A * 8590A * 8590A 1.5G spectrum analyzer HP 9kHz-1.5GHz 8590A |? HP-8590A ? Shenzhen used HP Spectrum Analyzer Model: 8590A Series briefly Brand: Hewlett-Packard HP Agilent Agilent Frequency range: HP 8590A: 9kHz ~ 1.5GHz; minimum interval of 1kHz (Option 130) HP 8591A:?? 9kHz ~ 1.8GHz; minimum interval 1kHz (Option 130) HP 8594A: 9kHz ~ 2.9GHz; minimum interval of 1kHz (Option 130) HP 8595A: 9kHz ~ 6.5GHz; minimum interval of 1kHz (Option 130) HP 8596A: 9kHz ~ 12.8 GHz; The minimum interval [1 × N] kHz (Option 130) HP 8593A: 9kHz ~ 22 GHz; minimum interval [1 × N] kHz (Option 130) portable spectrum analyzer details 8590A * The ease of use,?? can be extended harmonic spectrum analyzer * There is a diverse range of price and performance * with a selectable button for FFT, TOI, ACP and other measurements * with extended memory and a tracer storage * Optional narrow resolution bandwidth * can provide customized special test software HP8590A Series Spectrum Analyzer HP8590A Series spectrum analyzer with a wide range of performance, functionality, and its price is also the ability to adapt to the user and determined. Analyzer Users can lower priced basic performance until the high performance analyzers in the selection, the choice of which analyzer will feel HP8590A Series spectrum analyzer easy to use and highly reliable. These instruments scalability features make it easy to meet user requirements by increasing the measurement configuration. Use application testing software, allows the analyzer to apply to certain specific testing, such as cable television, electromagnetic compatibility (EMC), radio communications, noise figure and scalar network analysis measurements. Users can also purchase a variety of printers, plotters, and other accessories. A spectrum analyzer is suitable for a variety of applications the user can change the series spectrum analyzer test capabilities to meet specific measurement requirements. Memory card reader can be loaded into dedicated measurement software. Sophisticated measurement program is reduced to a key input. HP8590A series unique option card slot allows the addition of a circuit card options for the completion of additional functions. The optional built-in tracking generator provides for incentives - response to the synchronization signal source scanning measurement. Operate any kind HP8590A spectrum analyzer series requires only minimal training. There are many easy to use features make control and analysis of the measurements on the measurement results easier. This series spectrum analyzers have built-in automatic calibration to ensure consistency in the measurements. Panoramic sweep can be quickly re-established position signal, without having to repeat the scan. Internal memory can store more than 50 tracer, but using the memory card reader can be more tracer stored on RAM. The time and date indicated in a standard manner. Use HP-IB / parallel or RS-232 / parallel interface options, the results can be output directly to a printer or plotter. The option supports HP printers and certain designated Epson printer. For HP8590A Series PC software newly developed HP BenchLink Spectrum Analyzer PC software between PC and HP8590A Series spectrum analyzers establishment of a convenient communication links. By leveraging the Windows interface, users can easily screen image or tracer data via HP-IB or RS-232 interface to transfer, thereby simplifying the process in the PC environment measurement results acquisition, analysis and recording. HP8591A, 8593A, 8594A, 8595A and 8596A spectrum analyzer that some would harmonic spectrum analyzer RF, microwave and digital applications bring powerful integrated measurement capability. Five models from 9kHz start frequency and extending to 26.5GHz coverage options. Performance specifications include low phase noise of -105dBc at 30kHz offset at and have 2.1kHz frequency synthesizer accuracy at 1GHz. Use optional precision frequency reference, frequency synthesizer accuracy can be increased to 210Hz. Second and third, respectively, the dynamic range is 77 and 90dB. Use 130 option, the calibrated amplitude range is + 30 ~ -130dBm, only school-screen display is 70dB. With the optional circuit board that provides 30,100,200EMI and narrow resolution bandwidth of 30Hz. The circuit card ready for installation onto these analyzers. Standard Features window feature displays the screen into two horizontal areas, allowing the user to trace key part of the measurement are shown scaled or simultaneous display of test data and tracer. It has many standard single button measurements including frequency standard table, FFT (Fast Fourier Transform), NdB bandwidth and third-order intercept, amplitude modulation percentages and adjacent channel power. Built-in memory card reader allows the use of 32k, 128k, 256k and 512k memory card into the measurement application software, the user's own specific programs and measurement data. A variety of options increasing the number of circuit card option provides more measurement functions. The circuit card slot easily into the built-ins, most of the circuit card can be updated. Circuit card options include: ● 30,100,200EMI and narrow resolution bandwidth of 300Hz ● Timing gated spectrum analysis ● "Analog +" display and fast time-domain scan ● AM / FM demodulator ● TV receiver / Video Tester ● quasi-peak detector ● ● noise figure measurements for CT2-CAI and DECT ● demodulator for GSM900, DCS-1800, PCS-1900, NADC-TDMA, PHS, CDMA and PDC digital wireless communications standard demodulator and (or) digital signal processing. It provides built-in 1.8GHz tracking generator (renewable), and provide 2.9GHz tracking generator as HP8593A, 8594A, 8595A and 8596A is HP8591A. HP85902 burst carrier can provide TTL trigger reference to the timing of the digital wireless communication measurements. Technical indicators Unless otherwise noted, the following specifications apply to the several types of analyzer Frequency frequency range HP 8591A 50Ω:? 9kHz ~ 1.8GHz 75Ω: 1MHz ~ 1.8GHz HP 8594A: 9kHz ~ 2.9GHz (DC-coupled) , 100kHz ~ 2.9GHz (AC coupling) HP 8595A: 9 kHz ~ 6.5GHz (DC-coupled), 100kHz ~ 6.5GHz (AC coupling) frequency reference Aging rate: ± 2 × 10-6 / years, ± 1 × 10-7 / year (Option 004) temperature stability: ± 5 × 10-6, ± 1 × 10-8 (Option 004) Initial Accuracy: ± 0.5 × 10-6, ± 2.2 × 10-8 (Option 004) frequency readout accuracy (at the beginning, to the end of the central office, at a frequency standard) :? ± (frequency indication × frequency reference error + Interval Accuracy + 20% interval of 1% + RBW of + 100Hz × N) frequency standard count precision interval ≤10MHz × N: ± (frequency standard frequency × frequency reference error + counter resolution + 100Hz × N) interval> 10MHz × N: ± (frequency standard frequency × frequency reference error + counter resolution + 1kHz × N? ) counter resolution interval ≤10MHz × N: can select between 10Hz ~ 100kHz interval> 10MHz × N: can choose between 100Hz ~ 100kHz frequency interval range:? 0Hz (zero sweep interval) and HP 8591A: 10kHz ~ 1.8GHz; minimum interval of 1kHz (Option 130) HP 8594A: 10kHz ~ 2.9GHz; minimum interval of 1kHz (Option 130) HP 8595A: 10kHz ~ 6.5GHz; minimum interval of 1kHz (Option 130) HP 8596A: [ 10 × N] kHz ~ 12.8 GHz; minimum interval [1 × N] kHz (Option 130) HP 8593A: [10 × N] kHz ~ 19.25 GHz; minimum interval [1 × N] kHz (Option 130? ) Resolution: 4 digits or 20Hz × N, whichever is greater Accuracy: interval ≤10MHz × N: ± 2% interval interval> 10MHz × N: ± 3% scan time interval: Interval = 0Hz or> 1kHz: 20ms ~ 100s interval = 0Hz (Option 101) 20μs ~ 100s Accuracy: 20ms ~ 100s: ± 3% 20μs <20ms (Option 101): ± 2% scan trigger: Self-excited, a single power supply, ? Video, External Resolution Bandwidth: 1kHz ~ 3MHz (3dB), according to the order of sub-file 1,3,10; 9kHz and 120 kHz (6dB) EMI bandwidth. Option 130 an increase of 30,100 and 300Hz (3dB) bandwidth and 200 Hz (6dB) EMI Bandwidth Accuracy: ± 20% selectivity (typical) -60dB / -30dB: 3kHz ~ 10kHz, 15: 1 100kHz ~ 3MHz, 15 : 1 1kHz, 3kHz, 16: 1 -40dB / -3dB: 30Hz ~ 300Hz, 10: 1 video bandwidth range: 30Hz ~ 1MHz, according to the order of 1.3 BINS (with 130 option is 1Hz ~ 1MHz) stability noise sidebands band (1kHz RBW, 30Hz VBW, sample detector) and continuous wave signal deviations> 10kHz: ≤-90dBc / Hz + 20logN continuous wave signal deviations> 20kHz: ≤-100dBc / Hz + 20logN and continuous wave signal deviation > 30kHz: ≤-105dBc / Hz + 20logN residual FM HP 8591A: 1kHz RBW, 1kHz VBW: ≤250Hz pk-pk (100ms) 30Hz RBW, 30Hz VBW: ≤30Hz pk-pk (300ms) HP 8593A, HP 8594A, HP 8595A, HP 8596A: 1kHz RBW, 1kHz VBW: ≤ (250 × N) Hz pk-pk (100ms) 30Hz RBW, 30Hz VBW: ≤ (30 × N) Hz pk-pk (300ms) system-related side band (and continuous wave signal deviations> 30kHz): ≤-65dBc + 20logN frequency comb generator (HP 8593A, HP 8596A):?? 100MHz fundamental frequency; ± 0.007% frequency accuracy of amplitude amplitude range: the displayed average noise level ~ + 30dBm HP 8591A Option 001: the displayed average noise level ~ + 72dBmV maximum safe input level (input attenuator ≥10dB) Average continuous power:? + 30dBm (1W) HP 8591A Option 001: + 72dBmV (0.2W ) peak pulse power HP 8591A: + 30dBm (1W) HP 8591A Option 001:? + 72dBmV (0.2W) HP 8593A, HP 8594A, HP 8595A, HP 8596A: + 50dBm (100W), the pulse width <10μs, accounting Empty than <1% and the input attenuation ≥30dB DC HP 8591A: 100Vdc HP 8593A:: 0Vdc HP 8594A, HP 8595A, HP 8596A: 0V (DC-coupled): 50V (AC coupling) gain? 001 25Vdc HP 8591A options? ? Compression (> 10MHz): ≤0.5dB (total power input on the mixer = -10dBm) Power requirements: on (line 1): 195 ~ 250 Vrms, 47 ~ 66Hz power consumption <500VA; <180W Standby ( 0 line): Power consumption <7W user program memory (rated):? 238KB non-volatile RAM data storage (nominal) Inside: 24 tracer or 32 state external: 50 tracer, eight state memory cards: HP 85700A (32KB), 24 条 tracer or 32 state; HP 85702A (128KB), 99 条 tracer or 128 state videocassette recorders (VCR):? provides continuous video display from the composite video output Dimensions (nominal, without handle, stand or Nonproliferation cover) :? 325mm (width) × 163mm (high) × 427mm (length) Weight: 14.5kg (HP 8591A) ;? 16.4kg (HP 8593A, HP 8594A, HP 8595A, HP 8596A) Option 010 and 011 built-in tracking generator option 010 (50Ω) can be used for HP 8590A Series spectrum analyzer. Option 011 (75Ω) is only available for HP 8591A frequency range Option 010: 100kHz ~ 1.8GHz (HP 8591A) ;? 9kHz ~ 2.9kHz (HP 8593A, HP 8594A, HP 8595A, HP 8596A) Option 011: 1MHz ~ 1.8GHz (HP 8591A) output level range Option 010: 0 ~ -70dBm (HP 8591A); - 1 ~ -66dBm (HP 8593A, HP 8594A, HP 8595A, HP 8596A) Option 011: + 42.8 ~ -27.2 dBmV (HP 8591A) Resolution: 0.1dB absolute accuracy:? ± 1.0dB (HP 8591A) ± 0.75dB (HP 8593A, HP 8594A, HP 8595A, HP 8596A) trimming range:? 10dB (HP 8591A) ;? 9dB ( HP 8593A, HP 8594A, HP 8595A, HP 8596A) Accuracy: ± 0.75dB (HP 8591A) ;? ± 0.5dB (HP 8593A, HP 8594A, HP 8595A, HP 8596A) output flatness: ± 1.75dB (HP 8591A) ?; ± 2.0dB,> 10MHz (HP 8593A, HP 8594A, HP 8595A, HP 8596A) spurious output harmonic spurious signals: 0dBm + 42.8dBmV output, <- 25dBc (HP 8591A); - 1dBm output, <- 25dBc? (HP 8593A, HP 8594A, HP 8595A, HP 8596A?) non-harmonic spurious signals: <- 30dBc (HP 8591A); ≤-27dBc, 300kHz ~ 2.0GHz, ≤-23dBc, 2.0GHz ~ 2.9GHz (HP 8593A, ? HP 8594A, HP 8595A, HP 8596A) dynamic range (typical value, the maximum output level - trigger feedthrough) Option 010: 106dB (HP 8591A), 106dB (HP 8594A,> 400kHz) ,? 109dB (HP 8595A, HP 8596A,> 400kHz); 111dB (HP 8593A,> 400kHz) Option 011: 100dB power sweep range of options 010: -75dBm ~ 0dBm (HP 8591A), - 66dBm ~ -1dBm, with 8dB increase (? HP 8593A, HP 8594A, HP 8595A, HP 8596A) Option 011:? -32.2 ~ + 42.8dBmV (HP 8591A) Resolution: 0.1dB military general indicators of environmental indicators index: Class 3 military firmly in line with standard chassis calibration cycle: 2 years (8560EC / 61EC / 62EC / 63EC); 1 Year (8564EC / 65EC) Warm-up time: under normal ambient conditions of 5 minutes Temperature: -10 ° ~ + 55 ℃ (work); - 51 ° ~ + 71 ℃ (when not working) Humidity: 95%, at 40 ℃ condition persists for five days Waterproof: impermeable rainfall height at 16 l / hr / ft 2: 15,000 feet (operating); 50,000 feet (not working when the) pulse shock (half-sine): 30g, 11ms duration transport trailers: There are six faces and eight corners 8 inches trailers EMC: conducted and radiated interference in line with CISPR Pub.11 (1990). In addition to some indicators, are to meet MIL-STD-461 C part4 standards. Note: The long-term cash / recovery: network analyzer, spectrum analyzer, tester, digital communications test instrument, wireless tester, high frequency signal sources, oscilloscopes, LCR tester, Bluetooth tester, video and audio analysis instrument, logic analyzers, multimeters, Mobile programmable power supply, DC power supply. And sales / maintenance / acquisition / lease these instruments. Welcome to inquire!!! |
Admin>>>
You are the 11739 visitor
Copyright © GuangDong ICP No. 10089450, Bao'an District, Shenzhen, Qian Feng electronic equipment firms All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 11739 visitor
Copyright © GuangDong ICP No. 10089450, Bao'an District, Shenzhen, Qian Feng electronic equipment firms All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility